Fluke Networks DSX2-5000 CableAnalyzer - DSX2-5000

Fluke Networks DSX2-5000 CableAnalyzer - DSX2-5000

Regular price £8,741.90 GBP

THE NEW AND UPDATED DSX-5000: VERSION 2 WITH BUILT IN WIFI

Accelerates every step of the copper certification process

  • Versiv™ modular design supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
  • Taptive™ user interface simplifies set-up and eliminates errors
  • Analyse test results and create professional test reports using LinkWare™ management software
  • Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Endorsed by cabling vendors worldwide
  • Built in Alien Crosstalk testing capability
  • Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

The DSX CableAnalyzer Series copper test solution enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyse and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand..

The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. 

Features

  • ProjX™ Management System Manages Complex Jobs with Ease
  • Taptive™ User Interface Simplifies Set Up, Eliminates Errors and Speeds Troubleshooting
  • Performs with Unsurpassed Speed
Cable Types
Shielded and unshielded pair LAN cabling TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adapters Plug type: shielded RJ45
Optional Plug type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IEC Class C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequency DSX-8000: 2000 MHz;
DSX-5000: 1000 MHz
General Specifications
Speed of Autotest DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with shock absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote: Lithium ion battery pack, 7.2 V
Typical battery life: 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Environmental Specifications
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -14°F to +140°F (-10°C to +60°C)
Operating relative humidity 0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1
Performance Specifications **
DSX-8000 Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G
Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI
DSX-5000 Category 6A/Class EA test modes (or lower link categories) Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes Exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling1
  Without Remote With Remote
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation Delay
  Without Remote With Remote
Range 4000 ns 750 ns
Resolution 1 ns 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Part Number Description
DSX2-5000

1 Versiv Mainframe & Remote, (2) DSX-5000 CableAnalyzer Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStrap, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, (2) Universal Couplers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.

DSX2-ADD-R

1 Versiv 2 Remote, (2) DSX-5000 CableAnalyzer Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, Versiv Open Source Software CD, (2) AC Chargers, (2) Universal Couplers, Statement of Calibration and Getting Started Guide (Requires a Versiv 2 mainframe)