SimpliFiber® Pro Optical Power Meter - SFPOWERMETER is a simple-to-use fibre-loss tester with advanced time-saving features.
Various kits available with configurations to meet your fibre verification, inspection, and cleaning needs.
Features
- SimpliFiber Pro Kit Configurations
 - Fiber Inspection
 - Fiber Cleaning
 - Results Management
 - Verify and Locate Faults
 - Unique Capabilities
 
Specifications
| Environmental Specifications | |
| Operating Temperature | -10º C to 50º C | 
| Storage Temperature | -20º C to 50º C | 
| Operating Humidity | 
  | 
| EMI, RFI, EMC | Standards compliant1 | 
1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
| Optical Power Meter | |
| Detector Type | InGaAs | 
| Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm | 
| Measurement Range | 
  | 
| Power Measurement Linearity | 
  | 
| Power Measurement Uncertainty3 | ±0.25 dB | 
| Display Resolution, dB or dBm | 0.01 dB | 
| Auto Dual-Wavelength Switching | Yes | 
| Power Display Units | dBm, mW, μW | 
| Auto-Wavelength Detection | Yes | 
| Data Storage | 1000 records, multiple wavelengths per record | 
| External Interface | USB, 2.0 full speed | 
| Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST | 
| Display update rate | 1 reading per second | 
| Reference | Individually set for each wavelength | 
| FindFiber ID detection | Yes | 
| Power Requirement | 2 AA Alkaline batteries | 
| Battery Life4 | > 50 Hours (typical) | 
| Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) | 
| Low Battery Warning | Yes, low battery icon blinks | 
| Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) | 
| Weight | 11.5 oz (325 grams) | 
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
| Emitter Type | LED | 
| Central Wavelength | 850 nm, 1300 nm | 
| Wavelength Accuracy | 
  | 
| Spectral Width (FWHM) | 
  | 
| Minimum Output Power | 850/1300 nm: ³ -20 dBm | 
| Power Output Stability1 | ±0.1 dB over 8 hours | 
| Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. | 
| Optical Output Connector | Fixed SC | 
| FindFiber Code Generation | Yes. Fixed at ID 1. | 
| Modes | CW, 2 kHz modulated, Auto-wavelength | 
| Power Requirement | 2 AA Alkaline batteries. | 
| Battery Life2 | 40 hrs (typical) | 
| Automatic Power Off | 30 minutes (can be disabled by user) | 
| Low Battery Warning | Yes, LED blinks | 
| Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) | 
| Weight | 1.8 oz (278 g) | 
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
        
      
  
        
  
        
  
        